Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 302
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Anal Chim Acta ; 1301: 342413, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38553129

RESUMEN

Two-dimensional (2D) cultures do not fully reflect the human organs' physiology and the real effectiveness of the used therapy. Therefore, three-dimensional (3D) models are increasingly used in bioanalytical science. Organ-on-a-chip systems are used to obtain cellular in vitro models, better reflecting the human body's in vivo characteristics and allowing us to obtain more reliable results than standard preclinical models. Such 3D models can be used to understand the behavior of tissues/organs in response to selected biophysical and biochemical factors, pathological conditions (the mechanisms of their formation), drug screening, or inter-organ interactions. This review characterizes 3D models obtained in microfluidic systems. These include spheroids/aggregates, hydrogel cultures, multilayers, organoids, or cultures on biomaterials. Next, the methods of formation of different 3D cultures in Organ-on-a-chip systems are presented, and examples of such Organ-on-a-chip systems are discussed. Finally, current applications of 3D cell-on-a-chip systems and future perspectives are covered.


Asunto(s)
Sistemas Microfisiológicos , Organoides , Humanos , Evaluación Preclínica de Medicamentos/métodos , Microfluídica
2.
Lab Chip ; 24(8): 2280-2286, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38506153

RESUMEN

Concentration gradient generation and mixed combinations of multiple solutions are of great value in the field of biomedical research. However, existing concentration gradient generators for single or two-drug solutions cannot simultaneously achieve multiple concentration gradient formations and mixed solution combinations. Furthermore, the whole system was huge, and required expensive auxiliary equipment, which may lead to complex operations. To address this problem, we devised a novel 3D microchannel network design, which is capable of creating all the desired mixture combinations and concentration gradients of given small amounts of the input solutions. As a proof of concept, the device we presented was verified by both colorimetric and fluorescence detection methods to test the efficiency. This can enable the implementation of one to three solutions with no driving pump and facilitate unique multiple types of more concentration gradients and mixture combinations in a single operation. We envision that this will be a promising candidate for the development of simplified methods for screening of the appropriate concentration and combination, such as various drug screening applications.


Asunto(s)
Técnicas Analíticas Microfluídicas , Microfluídica , Evaluación Preclínica de Medicamentos
3.
Biosensors (Basel) ; 14(2)2024 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-38392005

RESUMEN

The convergence of microfluidics and organ-on-a-chip (OoC) technologies has revolutionized our ability to create advanced in vitro models that recapitulate complex physiological processes [...].


Asunto(s)
Microfluídica , Ingeniería de Tejidos , Sistemas Microfisiológicos , Evaluación Preclínica de Medicamentos , Dispositivos Laboratorio en un Chip
4.
Lab Chip ; 24(5): 1494-1528, 2024 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-38318723

RESUMEN

Cardiovascular disease (CVD) is the leading cause of death worldwide, casting a substantial economic footprint and burdening the global healthcare system. Historically, pre-clinical CVD modeling and therapeutic screening have been performed using animal models. Unfortunately, animal models oftentimes fail to adequately mimic human physiology, leading to a poor translation of therapeutics from pre-clinical trials to consumers. Even those that make it to market can be removed due to unforeseen side effects. As such, there exists a clinical, technological, and economical need for systems that faithfully capture human (patho)physiology for modeling CVD, assessing cardiotoxicity, and evaluating drug efficacy. Heart-on-a-chip (HoC) systems are a part of the broader organ-on-a-chip paradigm that leverages microfluidics, tissue engineering, microfabrication, electronics, and gene editing to create human-relevant models for studying disease, drug-induced side effects, and therapeutic efficacy. These compact systems can be capable of real-time measurements and on-demand characterization of tissue behavior and could revolutionize the drug development process. In this review, we highlight the key components that comprise a HoC system followed by a review of contemporary reports of their use in disease modeling, drug toxicity and efficacy assessment, and as part of multi-organ-on-a-chip platforms. We also discuss future perspectives and challenges facing the field, including a discussion on the role that standardization is expected to play in accelerating the widespread adoption of these platforms.


Asunto(s)
Enfermedades Cardiovasculares , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Animales , Humanos , Evaluación Preclínica de Medicamentos , Microfluídica , Ingeniería de Tejidos , Dispositivos Laboratorio en un Chip , Enfermedades Cardiovasculares/tratamiento farmacológico
5.
Sensors (Basel) ; 24(3)2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38339741

RESUMEN

Iodine is an essential micronutrient for humans due to its fundamental role in the biosynthesis of thyroid hormones. As a key parameter to assess health conditions, iodine intake needs to be monitored to ascertain and prevent iodine deficiency. Iodine is available from various food sources (such as seaweed, fish, and seafood, among others) and dietary supplements (multivitamins or mineral supplements). In this work, a microfluidic paper-based analytical device (µPAD) to quantify iodide in seaweed and dietary supplements is described. The developed µPAD is a small microfluidic device that emerges as quite relevant in terms of its analytical capacity. The quantification of iodide is based on the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) by hydrogen peroxide in the presence of iodine, which acts as the catalyst to produce the blue form of TMB. Additionally, powder silica was used to intensify and uniformize the colour of the obtained product. Following optimization, the developed µPAD enabled iodide quantification within the range of 10-100 µM, with a detection limit of 3 µM, and was successfully applied to seaweeds and dietary supplements. The device represents a valuable tool for point-of-care analysis, can be used by untrained personnel at home, and is easily disposable, low-cost, and user-friendly.


Asunto(s)
Yodo , Técnicas Analíticas Microfluídicas , Humanos , Microfluídica , Yoduros , Suplementos Dietéticos/análisis , Yodo/análisis , Dispositivos Laboratorio en un Chip , Papel
6.
J Virol Methods ; 326: 114905, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38387695

RESUMEN

Plant virus detection and identification in crops is a pillar for disease management, import of crop material, production of clean stock plants and basic plant virology studies. In this report, we present a platform for the enrichment and isolation of known or unknown viruses. This platform is based on carbon nanotube arrays inside a microfluidic device that can be a solution for the identification of low titer viruses from plants. Using our microfluidic devices, we achieved enrichment of two economically important viruses, the orthotospovirus, tomato spotted wilt orthotospovirus (TSWV) and the potyvirus, zucchini yellow mosaic virus (ZYMV). The carbon nanotube arrays integrated in these microfluidic devices are capable of trapping viruses discriminated by their size; the virus rich arrays can be then analyzed by common downstream techniques including immunoassays, PCR, HTS and electron microscopy. This procedure offers a simple to operate and portable sample preparation device capable of trapping viruses from raw plant extracts while reducing the host contamination.


Asunto(s)
Nanotubos de Carbono , Virus de Plantas , Microfluídica , Enfermedades de las Plantas
7.
Lab Chip ; 24(5): 1307-1326, 2024 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-38247405

RESUMEN

High-throughput microfluidic systems are widely used in biomedical fields for tasks like disease detection, drug testing, and material discovery. Despite the great advances in automation and throughput, the large amounts of data generated by the high-throughput microfluidic systems generally outpace the abilities of manual analysis. Recently, the convergence of microfluidic systems and artificial intelligence (AI) has been promising in solving the issue by significantly accelerating the process of data analysis as well as improving the capability of intelligent decision. This review offers a comprehensive introduction on AI methods and outlines the current advances of high-throughput microfluidic systems accelerated by AI, covering biomedical detection, drug screening, and automated system control and design. Furthermore, the challenges and opportunities in this field are critically discussed as well.


Asunto(s)
Inteligencia Artificial , Microfluídica , Automatización , Evaluación Preclínica de Medicamentos
8.
Biosensors (Basel) ; 14(1)2024 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-38275308

RESUMEN

The development of therapeutic interventions for diseases necessitates a crucial step known as drug screening, wherein potential substances with medicinal properties are rigorously evaluated. This process has undergone a transformative evolution, driven by the imperative need for more efficient, rapid, and high-throughput screening platforms. Among these, microfluidic systems have emerged as the epitome of efficiency, enabling the screening of drug candidates with unprecedented speed and minimal sample consumption. This review paper explores the cutting-edge landscape of microfluidic-based drug screening platforms, with a specific emphasis on two pioneering approaches: organ-on-a-chip and C. elegans-based chips. Organ-on-a-chip technology harnesses human-derived cells to recreate the physiological functions of human organs, offering an invaluable tool for assessing drug efficacy and toxicity. In parallel, C. elegans-based chips, boasting up to 60% genetic homology with humans and a remarkable affinity for microfluidic systems, have proven to be robust models for drug screening. Our comprehensive review endeavors to provide readers with a profound understanding of the fundamental principles, advantages, and challenges associated with these innovative drug screening platforms. We delve into the latest breakthroughs and practical applications in this burgeoning field, illuminating the pivotal role these platforms play in expediting drug discovery and development. Furthermore, we engage in a forward-looking discussion to delineate the future directions and untapped potential inherent in these transformative technologies. Through this review, we aim to contribute to the collective knowledge base in the realm of drug screening, providing valuable insights to researchers, clinicians, and stakeholders alike. We invite readers to embark on a journey into the realm of microfluidic-based drug screening platforms, fostering a deeper appreciation for their significance and promising avenues yet to be explored.


Asunto(s)
Ensayos Analíticos de Alto Rendimiento , Microfluídica , Animales , Humanos , Caenorhabditis elegans , Evaluación Preclínica de Medicamentos , Sistemas Microfisiológicos , Dispositivos Laboratorio en un Chip
9.
Anal Chim Acta ; 1287: 342053, 2024 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-38182365

RESUMEN

Rapid and specific detection of virulent bacterial strains is a great challenge for food safety regarding large amounts of contaminated samples. Herein, a dual-mode hydrogel array biosensor was constructed to simultaneously rapidly screen and precisely quantitatively detect virulent Escherichia coli O157:H7 (E. coli O157:H7) based on a novel DNA-modified phage probe. First, E. coli O157:H7 was incubated with alginate to form the E. coli O157:H7/hydrogel premix complex. Subsequently, hydrogel formation by cross-linking upon the addition of calcium ions and phages for E. coli O157:H7 modified with a DNA primer (phage-DNA) was added to the alginate hydrogel. The DNA on the complex could trigger rolling circle amplification (RCA) to form a phage probe containing a long-chain DNA skeleton (phage@RCA-DNA). The RCA-DNA was then hybridized with the complementary DNA (cDNA) to form double-stranded DNA fragments (phage@RCA-dsDNA), which could be stained by the SYBR Green dye to emit visual green fluorescence (FL) and determined by a smartphone for rapid screening. Meanwhile, the unreacted cDNA in the supernatant could be quantitatively detected by microfluidic chip electrophoresis (MCE). The signal decrement was also proportional to the bacterial concentration. The detection limit values of E. coli O157:H7 were 50 CFU mL-1 by the FL signal and 6 CFU mL-1 by the MCE signal. The two results could be mutually corrected to decrease the false-positive results. This assay was also employed to detect virulent Salmonella Typhimurium (S. Typhimurium) using the corresponding S. Typhimurium phage@RCA-DNA probe. All these results demonstrated that the universal bioassay was suitable for simultaneous rapid screening and precisely quantitative detection of virulent bacterial strains.


Asunto(s)
Bacteriófagos , Escherichia coli O157 , ADN Complementario , Hidrogeles , Microfluídica , Sondas de ADN , Alginatos , Colorantes , Electroforesis
10.
Int J Biol Macromol ; 254(Pt 1): 127763, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37924901

RESUMEN

Gastric cancer is the fifth most frequently diagnosed malignant neoplasm and the third leading cause of cancer-related mortality. Nevertheless, the therapeutic efficacy of conventional surgical and chemotherapeutic interventions in clinical practice is often unsatisfactory. Curcumin (Cur) has shown promise as a therapeutic agent in prior studies. However, its progress in this context has been impeded by challenges including low solubility, instability in aqueous environments, and rapid metabolism. In this study, we develop methacrylate fish gelatin (FGMA) hydrogel microparticles (FGMPs@Cur) encapsulating Cur via microfluidic electrospray technology for postoperative comprehensive treatment of gastric cancer. Comprehensive characterizations and analyses were conducted to assess the cytotoxicity against gastric cancer cells and potential tissue reparative effects of FGMPs@Cur. In vitro experiments revealed that FGMPs@Cur exhibited a remarkable cytotoxic effect on nearly 80 % of gastric cancer cells while maintaining at least 95 % viability of normal cells in cell compatibility tests. In vivo results demonstrated that FGMPs@Cur significantly reduced tumor volume to 47 % of the control group, and notable tissue regeneration was observed at the surgical site. These properties indicated that such a hydrogel microparticle system is a promising candidate for postoperative gastric cancer treatment in practical application.


Asunto(s)
Curcumina , Nanopartículas , Neoplasias Gástricas , Animales , Curcumina/farmacología , Gelatina , Neoplasias Gástricas/tratamiento farmacológico , Microfluídica , Hidrogeles , Línea Celular Tumoral
11.
Lab Chip ; 23(24): 5139-5150, 2023 12 05.
Artículo en Inglés | MEDLINE | ID: mdl-37942508

RESUMEN

3D in vitro biological systems are progressively replacing 2D systems to increase the physiological relevance of cellular studies. Microfluidics-based approaches can be powerful tools towards such biomimetic systems, but often require high-end complicated and expensive processes and equipment for microfabrication. Herein, a drug screening platform is proposed, minimizing technicality and manufacturing steps. It provides an alternate way of spheroid generation in droplets in tubes. Droplet microfluidics then elicit multiple droplets merging events at programmable times, to submit sequentially the spheroids to chemotherapy and to reagents for cytotoxicity screening. After a comprehensive study of tumorogenesis within the droplets, the system is validated for drug screening (IC50) with chemotherapies in cancer cell lines as well as cells from a patient-derived-xenografts (PDX). As compared to microtiter plates methods, our system reduces the initial number of cells up to 10 times and opens new avenues towards primary tumors drug screening approaches.


Asunto(s)
Microfluídica , Neoplasias , Humanos , Microfluídica/métodos , Evaluación Preclínica de Medicamentos , Detección Precoz del Cáncer , Esferoides Celulares , Línea Celular Tumoral , Neoplasias/tratamiento farmacológico
12.
Anal Bioanal Chem ; 415(29-30): 7151-7160, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37804326

RESUMEN

Flavonoids are a class of secondary plant metabolites with low molecular weights. Most flavonoids are highly polar and unsuitable for gas chromatographic analyses. Derivatization is commonly used to make them amenable to gas chromatography by altering their physicochemical properties. Although highly effective, derivatization techniques introduce extra preparation steps and often use hazardous chemicals. The aim of this study was to automate derivatization (specifically, silylation) by developing 3D printed microfluidic devices in which derivatization of flavonoids can occur. A microfluidic device was designed and 3D printed using clear polypropylene. Quercetin and other flavonoids (TED 13 and ZTF 1016) isolated from plant extracts were silylated with N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide (MTBSTFA) at room temperature both in batch and in continuous flow. All the samples were analyzed using Fourier transform infrared (FTIR) spectroscopy, gas chromatography combined with mass spectrometry (GC-MS), and high-resolution accurate mass spectrometry (HR-MS). Interestingly, the HR-MS results showed that the flow method was about 25 times more efficient than the batch method for quercetin samples. The TED 13 flavonoid was completely derivatized in the flow method compared to the batch method where the reaction was incomplete. Similar results were observed for ZTF 1016, where the flow method resulted in a four times derivatized compound, while the compound was only derivatized once in batch. In conclusion, 3D printed microfluidic devices have been developed and used to demonstrate a semi-automated, inexpensive, and more efficient natural product derivatization method based on continuous flow chemistry as an alternative to the traditional batch method.


Asunto(s)
Flavonoides , Quercetina , Cromatografía de Gases y Espectrometría de Masas/métodos , Microfluídica , Impresión Tridimensional
13.
Anal Bioanal Chem ; 415(27): 6873-6883, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37792070

RESUMEN

Over the past two decades, microfluidic-based separations have been used for the purification, isolation, and separation of biomolecules to overcome difficulties encountered by conventional chromatography-based methods including high cost, long processing times, sample volumes, and low separation efficiency. Cyclotides, or cyclic peptides used by some plant families as defense agents, have attracted the interest of scientists because of their biological activities varying from antimicrobial to anticancer properties. The separation process has a critical impact in terms of obtaining pure cyclotides for drug development strategies. Here, for the first time, a mimic of the high-performance liquid chromatography (HPLC) on microfluidic chip strategy was used to separate the cyclotides. In this regard, silica gel-C18 was synthesized and characterized by Fourier-transform infrared spectroscopy (FTIR) and proton nuclear magnetic resonance (1H-NMR) and then filled inside the microchannel to prepare an HPLC C18 column-like structure inside the microchannel. Cyclotide extract was obtained from Viola ignobilis by a low voltage electric field extraction method and characterized by HPLC and matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF). The extract that contained vigno 1, 2, 3, 4, 5, and varv A cyclotides was added to the microchannel where distilled water was used as a mobile phase with 1 µL/min flow rate and then samples were collected in 2-min intervals until 10 min. Results show that cyclotides can be successfully separated from each other and collected from the microchannel at different periods of time. These findings demonstrate that the use of microfluidic channels has a high impact on the separation of cyclotides as a rapid, cost-effective, and simple method and the device can find widespread applications in drug discovery research.


Asunto(s)
Ciclotidas , Viola , Secuencia de Aminoácidos , Ciclotidas/análisis , Ciclotidas/química , Gel de Sílice , Microfluídica , Viola/química , Extractos Vegetales
14.
J Pharm Biomed Anal ; 236: 115724, 2023 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-37729745

RESUMEN

BACKGROUND: Herbal extracts contain multiple active constituents, so the sample preparation based on the liquid-liquid extraction (LLE) is demanding, especially when a study subsequent to extraction is needed. Since the laminar flow occurring in microchannels can be formed between two miscible organic phases, a new method of extracting polar compounds from the crude extract of Panax ginseng Meyer in aqueous ethanol by pure n-butanol in the three-phase laminar flow microfluidic chip was established. METHODS: A new chip consisting of long microchannels with a guide structure was employed to improve the extraction efficiency caused by the low diffusion ability of saponins. The method was evaluated by using the extraction yields and purities of ginsenosides Rg1, Re and Rb1 as the indicators, and extraction conditions such as flow rate, temperature and other governing factors were optimized. RESULTS: Using the new chip method, the extraction efficiencies of ginsenoside Rg1, Re and Rb1 were 63.1%, 69.5% and 71.6%, respectively, which are higher than the 26% achieved in a previous report. The extraction yields of 1.53, 0.51, 0.90 mg/g were also higher than those obtained previously by the successive laminar flow microchip method. CONCLUSION: The proposed new microfluidic chip method has simplified the sample pretreatment steps to improve the yield of ginsenoside extraction from ginseng samples.


Asunto(s)
Ginsenósidos , Panax , Saponinas , Ginsenósidos/análisis , Panax/química , Microfluídica , Saponinas/química , Agua , Cromatografía Líquida de Alta Presión/métodos
15.
Lab Chip ; 23(18): 4067-4078, 2023 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-37610268

RESUMEN

Recent advances recognize that the viscoelastic properties of epithelial structures play important roles in biology and disease modeling. However, accessing the viscoelastic properties of multicellular structures in mechanistic or drug-screening applications has challenges in repeatability, accuracy, and practical implementation. Here, we present a microfluidic platform that leverages elastohydrodynamic phenomena, sensed by strain sensors made from graphene decorated with palladium nanoislands, to measure the viscoelasticity of cellular monolayers in situ, without using chemical labels or specialized equipment. We demonstrate platform utility with two systems: cell dissociation following trypsinization, where viscoelastic properties change over minutes, and epithelial-to-mesenchymal transition, where changes occur over days. These cellular events could only be resolved with our platform's higher resolution: viscoelastic relaxation time constants of λ = 14.5 ± 0.4 s-1 for intact epithelial monolayers, compared to λ = 13.4 ± 15.0 s-1 in other platforms, which represents a 30-fold improvement. By rapidly assessing combined contributions from cell stiffness and intercellular interactions, we anticipate that the platform will hasten the translation of new mechanical biomarkers.


Asunto(s)
Grafito , Transición Epitelial-Mesenquimal , Evaluación Preclínica de Medicamentos , Microfluídica
16.
Int J Pharm ; 643: 123256, 2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37482229

RESUMEN

The transdermal drug delivery system (TDDS) is an effective strategy for the treatment of melanoma with fewer side effects and good biocompatible, but the skin penetration of drugs should be further promoted. Here, we proposed a new system that combined curcumin liposomes (Cur-Lips) with skin-penetrating peptides to promote skin penetration ability. However, the preparation of Cur-Lips has drawbacks of instability and low entrapment efficiency by the traditional methods. We thus innovatively designed and applied a microfluidic chip to optimize the preparation of Cur-Lips. Cur-Lips exhibited a particle size of 106.22 ± 4.94 nm with a low polydispersity index (<0.3) and high entrapment efficiency of 99.33 ± 1.05 %, which were prepared by the microfluidic chip. The Cur-Lips increased the skin penetration capability of Cur by 2.76 times compared to its solution in vitro skin penetration experiment. With the help of skin-penetrating peptide TD-1, the combined system further promoted the skin penetration capability by 4.48 times. The (TD-1 + Cur-Lips) system also exhibited a superior inhibition effect of the tumor to B16F10 in vitro. Furthermore, the topical application of (TD-1 + Cur-Lips) gel suppressed melanoma growth in vivo, and induced tumor cell apoptosis in tumor tissues. The skin-penetration promotion mechanism of the system was investigated. It was proved that the system could interact with the lipids and keratin on the stratum corneum to promote the Cur distribute into the stratum corneum through hair follicles and sweat glands. We proved that the microfluidic chips had unique advantages for the preparation of liposomes. The innovative combined system of liposomes and biological transdermal enhancers can effectively promote the skin penetration effect of drugs and have great potential for the prevention and treatment of melanoma.


Asunto(s)
Curcumina , Melanoma , Humanos , Liposomas , Curcumina/farmacología , Microfluídica , Inhibidores de la Ciclooxigenasa , Melanoma/tratamiento farmacológico , Péptidos , Tamaño de la Partícula
17.
Methods Mol Biol ; 2679: 25-39, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37300607

RESUMEN

Rapid and accurate cancer drug screening is of great importance in precision medicine. However, the limited amount of tumor biopsy samples has hindered the application of traditional drug screening methods with microwell plates for individual patients. A microfluidic system provides an ideal platform for handling trace amounts of samples. This emerging platform has a good role in nucleic acid-related and cell related assays. Nevertheless, convenient drug dispensing remains a challenge for clinical on-chip cancer drug screening. Similar sized droplets are merged to add drugs for a desired screened concentration which significantly complicated the on-chip drug dispensing protocols. Here, we introduce a novel digital microfluidic system with a specially structured electrode (a drug dispenser) to dispense drugs by droplet electro-ejection under a high-voltage actuation signal, which can be conveniently adjusted by external electric controls. With this system, the screened drug concentrations span up to four orders of magnitude with small sample consumption. Various amounts of drugs can be delivered to the cell sample with desired amount in a flexible electric control. Moreover, single drug or combinatorial multidrug on-chip screening can be readily achieved. The drug response of normal MCF-10A breast cells and MDA-MB-231 breast tumor cells to two chemotherapeutic substances, cisplatin (Cis) and epirubicin (EP), was tested individually and in combination for proof-of-principle verification. The comparable on-chip and off-chip results confirmed the feasibility of our innovative DMF system for cancer drug screening.


Asunto(s)
Antineoplásicos , Técnicas Analíticas Microfluídicas , Humanos , Microfluídica/métodos , Técnicas Analíticas Microfluídicas/métodos , Evaluación Preclínica de Medicamentos , Antineoplásicos/farmacología , Cisplatino/farmacología
18.
Int J Biol Macromol ; 245: 125308, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37315661

RESUMEN

Metastasis is one of the major causes for cancer mortality. Its early steps comprise of invasion of basement membrane and migration. Thus, it is hypothesized that a platform, that allows quantification and grading of migration capability of cells can potentially be used for predicting metastatic potential. Two-dimensional (2D) models have been rendered inadequate for modelling in-vivo microenvironment due to various reasons. To attenuate homogeneity observed in 2D, three-dimensional (3D) platforms supplemented with bioinspired components have been designed. Unfortunately, till date there are no simple models to capture the migration of cells in 3D along with quantification of the process. In this study, we report an alginate-collagen based 3D model system, which can predict the migratory property of the cells within 72 h. The micron size of the scaffold enabled faster readout and the optimum pore-size provided conducive cellular growth environment. The platform's ability to allow observation of cellular migration was validated by encapsulating cells with transiently upregulated matrix metalloprotease 9 (MMP9), which has been reported to play a significant role in migration of cells during metastasis. The readout for migration was clustering of cells in the microscaffolds detected in a short span of 48 h. The observed clustering in MMP9 upregulated cells was validated by observing changes in the epithelial-mesenchymal transition (EMT) markers. Thus, this simple 3D platform can be used to study migration and predict the metastatic potential of cells.


Asunto(s)
Alginatos , Movimiento Celular , Colágeno , Andamios del Tejido , Alginatos/química , Alginatos/metabolismo , Biomarcadores de Tumor/metabolismo , Cadherinas/metabolismo , Colágeno/química , Colágeno/metabolismo , Transición Epitelial-Mesenquimal , Gelatina/metabolismo , Microfluídica , Metástasis de la Neoplasia , Porosidad , Andamios del Tejido/química , Factores de Transcripción Twist/metabolismo , Humanos , Línea Celular Tumoral
19.
Methods Mol Biol ; 2644: 435-447, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37142939

RESUMEN

High-throughput (HT) drug screening is in high demand for successful drug discovery and personalized medicine. Spheroids act as a promising preclinical model for HT drug screening, which may decrease drug failures in clinical trials. Numerous spheroid-forming technological platforms are currently under development, which include synchronous, jumbo-sized, hanging drop, rotary, and nonadherent surface spheroid growth. Initial cell seeding concentration and time of culture play a vital role for spheroids to mimic the extracellular microenvironment of natural tissue, especially for HT preclinical evaluation. Hence microfluidic platforms become a potential technology to provide a confined space for the oxygen and nutrient gradients within the tissues while controlling the cell count and spheroid size in an HT manner. We describe here a microfluidic platform capable of generating spheroids of multiple sizes in a controlled manner with a predefined cell concentration for HT drug screening. Ovarian cancer spheroids grown on this microfluidic platform were evaluated for viability using a confocal microscope and flow cytometer. In addition, screening of the HT chemotherapeutic drug carboplatin was carried out on-chip to evaluate the impact of spheroid size on drug toxicity. This chapter summarizes a detailed protocol on microfluidic platform fabrication for spheroid growth, on-chip multi-sized spheroid analysis, and chemotherapeutic drug screening.


Asunto(s)
Ensayos Analíticos de Alto Rendimiento , Esferoides Celulares , Femenino , Humanos , Ensayos Analíticos de Alto Rendimiento/métodos , Línea Celular Tumoral , Microfluídica/métodos , Evaluación Preclínica de Medicamentos
20.
ACS Biomater Sci Eng ; 9(6): 3402-3413, 2023 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-37140447

RESUMEN

Current anticancer research shows that a combination of multiple treatment methods can greatly improve the killing of tumor cells. Using the latest microfluidic swirl mixer technology, combined with chemotherapy and photothermal-ablation therapy, we developed multiresponsive targeted antitumor nanoparticles (NPs) made of folate-functionalized gelatin NPs under 200 nm in size and with encapsulated CuS NPs, Fe3O4 NPs, and curcumin (Cur). By exploring gelatin's structure, adjusting its concentration and pH, and fine-tuning the fluid dynamics in the microfluidic device, the best preparation conditions were obtained for gelatin NPs with an average particle size of 90 ± 7 nm. The comparative targeting of the drug delivery system (DDS) was demonstrated on lung adenocarcinoma A549 cells (low level of folate receptors) and breast adenocarcinoma MCF-7 cells (high level of folate receptors). Folic acid helps achieve targeting and accurate delivery of NPs to the MCF-7 tumor cells. The synergistic photothermal ablation and curcumin's anticancer activity are achieved through infrared light irradiation (980 nm), while Fe3O4 is guided with an external magnetic field to target gelatin NPs and accelerate the uptake of drugs, thus efficiently killing tumor cells. The method described in this work is simple, easy to repeat, and has great potential to be scaled up for industrial production and subsequent clinical use.


Asunto(s)
Antineoplásicos , Curcumina , Nanopartículas , Humanos , Curcumina/farmacología , Curcumina/química , Antineoplásicos/farmacología , Antineoplásicos/uso terapéutico , Gelatina , Microfluídica , Nanopartículas/química , Ácido Fólico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA